Equipment Details


N/Protein Analyser -TurboFlash Combustion Technology

>> Analytical Equipment
Model:

Chromline Equipment (I) Pvt.Ltd
Mumbai, Maharashtra - India
>> Equipment Manufacturer

Description & Specifications


System description. 
      EuroEA3017/Prot is a compact, fully automatic, fast analyser for very accurate N/Protein content determination.
      The straight-forward operation of this system is as follows: PC and Callidus software fully supervise all operations and in 60 seconds automatically enters sample weights from the balance, downloads pre-set parameters, activates the AutoSampler, controls the entire combustion process, acquires and handles data from a sample sequence, and reports results in one of several report forms. 
Sampling Integrity.
      For maximum accuracy in the analysis of non-homogeneous materials, 100-g of sample or more are processed and 10-100 mg are weighed, put in standard tin cups and directly introduced into the AutoSampler. The Analyser, taking advantage of TurboFlash Combustion Technology independently setting oxygen volume and pressure, assures complete combustion. This revolutionary technique gives maximum unattended runs and extreme accuracy both for homogeneous and non homogeneous sample.
TurboFlash Combustion. 
     This new patented technology dynamically combust sample in the most difficult matrices. Specific catalysts ensure that the conversion of the sample into the combustion gases is truly quantitative. CO2 and moisture are automatically removed by a single-step selective adsorption, leaving only Nitrogen in the Helium carrier flow. A high sensitivity TCD detector accurately measures N-Protein. Results are presented as percent protein content, your choice of report format is provided by the software. No methane is formed and no chromatographic column is required. The exhausted Reactor/Trap Assembly can be replaced in less than one minute. 
Nitrogen-Protein Analysis. 
A dedicated instrument is used in this field. Calibration, sample preparation and instrument operation for optimal performance can be achieved by following Help Desk recommendations, also directed to support extended operation, preventive maintenance and lowest cost per test.
AOAC compliance. 
     The EuroVector System meets AOAC recommendations for combustion methods for N/Protein analysis and guarantees extremely accurate analytical results as % Protein. 
Total solution. 
     Instruments are delivered factory-tested under a specific analytical protocol and installed by accredited field service engineers. EuroVector consumables are supplied with Materials Safety Data Sheets. Standard Reference Materials are accompanied by full certification documentation